Standard Type | C0/L0 Term Z | C1/L1 | C2/L2 | C3/L3 | Load Type | Offset Delay | Offset Z0 | Offset Loss | Min Freq | Max Freq | Medium | Standard Label |
| #1 | Short | 0 | 0 | 0 | 0 | Fixed | 66.73398 | 49.99999 | 0.63 | 0 | 999 | Coax | SHORT |
| #2 | Open | 32 | 99.99998 | -50.00001 | 99.99998 | Fixed | 66.73398 | 49.99999 | 0.63 | 0 | 998.001 | Coax | OPEN |
| #3 | Short | 0 | 0 | 0 | 0 | Fixed | 0 | 49.99998 | 0 | 0 | 999 | Coax |
|
| #4 | Short | 0 | 0 | 0 | 0 | Fixed | 0 | 49.99998 | 0 | 0 | 999 | Coax |
|
| #5 | Short | 0 | 0 | 0 | 0 | Fixed | 0 | 49.99998 | 0 | 0 | 999 | Coax |
|
| #6 | Short | 0 | 0 | 0 | 0 | Fixed | 0 | 49.99998 | 0 | 0 | 999 | Coax |
|
| #7 | Short | 0 | 0 | 0 | 0 | Fixed | 0 | 49.99998 | 0 | 0 | 999 | Coax |
|
| #8 | Short | 0 | 0 | 0 | 0 | Fixed | 0 | 49.99999 | 0 | 0 | 999 | Coax |
|
| #9 | Load |
|
Fixed | 0 | 49.99999 | 0 | 0 | 999 | Coax | BROADBAND | |||
| #10 | Load |
|
Sliding | 0 | 49.99999 | 0 | 0.9 | 999 | Coax |
| |||
| #11 | Thru |
|
Fixed | 0 | 49.99999 | 0 | 0 | 999 | Coax | THRU | |||
| #12 | Load |
|
Fixed | 0 | 49.99999 | 0 | 0 | 999 | Coax |
| |||
| #13 | Thru |
|
Fixed | 236.87097 | 49.99999 | 0.63 | 0 | 999 | Coax | APC-7 | |||
| #14 | Thru |
|
Fixed | 262.45095 | 49.99999 | 0.63 | 0 | 999 | Coax | TYPE-N | |||
| #15 | Thru |
|
Fixed | 165.96097 | 49.99999 | 0.63 | 0 | 999 | Coax | IN-SERIES | |||
| #16 | Short | 0 | 0 | 0 | 0 | Fixed | 0 | 49.99998 | 0 | 0 | 999 | Coax |
|
| #17 | Short | 0 | 0 | 0 | 0 | Fixed | 0 | 49.99998 | 0 | 0 | 999 | Coax | 8047B |
| #18 | Short | 0 | 0 | 0 | 0 | Fixed | 0 | 49.99998 | 0 | 0 | 999 | Coax |
|
| #19 | Short | 0 | 0 | 0 | 0 | Fixed | 0 | 49.99998 | 0 | 0 | 999 | Coax |
|
| #20 | Short | 0 | 0 | 0 | 0 | Fixed | 0 | 49.99998 | 0 | 0 | 999 | Coax |
|
| #21 | Short | 0 | 0 | 0 | 0 | Fixed | 0 | 49.99999 | 0 | 0 | 999 | Coax |
|
|
|
|||||||||||||
| Class Assignments |
|
||||||||||||
|
|
A | B | C | D | E | F | G | Standard Class Label |
|
||||
| S11A | 2 |
|
OPEN |
|
|||||||||
| S11B | 1 |
|
SHORT |
|
|||||||||
| S11C | 9 |
|
LOADS |
|
|||||||||
| S22A | 2 |
|
OPEN |
|
|||||||||
| S22B | 1 |
|
SHORT |
|
|||||||||
| S22C | 9 |
|
LOADS |
|
|||||||||
| Forward Transmission | 11 |
|
THRU |
|
|||||||||
| Reverse Transmission | 11 |
|
THRU |
|
|||||||||
| Forward Match | 11 |
|
THRU |
|
|||||||||
| Reverse Match | 11 |
|
THRU |
|
|||||||||
| Forward Isolation | 9 |
|
ISOL'N STD |
|
|||||||||
| Reverse Isolation | 9 |
|
ISOL'N STD |
|
|||||||||
| Frequency Response | 1 | 2 | 11 |
|
RESPONSE |
|
|||||||
| TRL Thru or Line | 1 |
|
TRL THRU |
|
|||||||||
| TRL Reflect | 1 |
|
TRLREFLECT |
|
|||||||||
| TRL Line or Match | 1 |
|
TRL LINE |
|
|||||||||
| Adapter | 13 | 14 | 15 |
|
ADAPTER |
|
|||||||
|
|
|||||||||||||
| VNA = Agilent 8510C |
|
||||||||||||
| System Z0 = 50 ohm |
|
||||||||||||
| TRL Set Ref = Thru |
|
||||||||||||
| TRL Cal Z0 = Line Z0 |
|
||||||||||||
| TRL Lowband Frequency = 2 GHz |
|
||||||||||||
|
|
|||||||||||||
|
|
|||||||||||||