85036B/E TypeN (75) Calibration Kit

Download 85036BE.ckt

 

 

 

 

 

 

 

 

 

 

 

 

 

Std. No.

Label

Description

Connector

Sex

C0 F(e-15)

C1 F(e-27)/Hz

C2 F(e-36)/Hz^2

C3 F(e-45)/Hz^3

Fmin (MHz)

Fmax (MHz)

Delay (Sec)

Loss (Gohm/Sec)

Z0 (Ohm)

6

OPEN -M-

Type N (75) male open

Type N (75)

MALE

41

40

5

0

0

999000

1.75E-11

1.13

75

2

OPEN -F-

Type N (75) female open

Type N (75)

FEMALE

63.5

84

56

0

0

999000

0.00E+00

1.13

75

 

Std. No.

Label

Description

Connector

Sex

L0 H(e-12)

L1 H(e-24)/Hz

L2 H(e-33)/Hz^2

L3 H(e-42)/Hz^3

Fmin (MHz)

Fmax (MHz)

Delay (Sec)

Loss (Gohm/Sec)

Z0 (Ohm)

1

SHORT -M-

Type N (75) male short

Type N (75)

MALE

0

0

0

0

0

999000

1.75E-11

1.13

75

5

SHORT -F-

Type N (75) female short

Type N (75)

FEMALE

0

0

0

0

0

999000

9.30E-13

1.13

75

 

Std. No.

Label

Description

Connector

Sex

Fixed/Sliding

Arbitary Imp

Offset Load

Fmin (MHz)

Fmax (MHz)

Delay (Sec)

Loss (Gohm/Sec)

Z0 (Ohm)

 

3

BROADBAND LOAD -M-

Type N (75) male broadband load

Type N (75)

MALE

FIXED

OFF

OFF

0

999000

0.00E+00

1.13

75

 

7

BROADBAND LOAD -F-

Type N (75) female broadband load

Type N (75)

FEMALE

FIXED

OFF

OFF

0

999000

0.00E+00

1.13

75

 

 

Std. No.

Label

Description

Connector Port1

Sex Port1

Connector Port2

 Sex Port2

Fmin (MHz)

Fmax (MHz)

Delay (Sec)

Loss (Gohm/Sec)

Z0 (Ohm)

 

4

THRU

Insertable thru standard

Type N (75)

FEMALE

Type N (75)

MALE

0

999000

0.00E+00

1.13

75

 

 

 

Connector

Description

Sex

Media

Min Freq(MHz)

Max Freq(MHz)

Cutoff Freq(MHz)

ψ

 

Type N (75)

Type N (75) male

MALE

COAX

0

999000

0

ψ

 

Type N (75)

Type N (75) female

FEMALE

COAX

0

999000

0

ψ

 

 

 

 

SOLT Class Assignments

 

 

Class Label

A

B

C

D

E

F

G

H

I

J

K

 

S11A

6

2

 

S11B

1

5

 

S11C

3

7

 

S22A

6

2

 

S22B

1

5

 

S22C

3

7

 

FWD MATCH

4

 

FWD TRAN

4

 

REV MATCH

4

 

REV TRAN

4

 

ISOLATION

3

7

 

 

 

TRL Class Assignments

 

 

Class Label

A

B

C

D

E

F

G

 

TRL THRU

 

TRL REFLECT

 

TRL LINE

 

FWD MATCH

 

REV MATCH

 

ISOLATION

3

7

 

 

Calibration Reference Z0 =

 

SYSTEM Z0

 

 

Testport Reference Plane =

 

THRU STANDARD