85059AP Polynomial 1.00 mm (Reduced Accuracy) |
Download 85059AP.ckt |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||
|
Std. No. |
Label |
Description |
Connector |
Sex |
C0 F(e-15) |
C1 F(e-27)/Hz |
C2 F(e-36)/Hz^2 |
C3 F(e-45)/Hz^3 |
Fmin (MHz) |
Fmax (MHz) |
Delay (Sec) |
Loss (Gohm/Sec) |
Z0 (Ohm) |
|
4 |
OPEN LB -F- |
1.00 mm female [OPEN] |
1.00 mm |
FEMALE |
29.27 |
360.024 |
-8.3672 |
0.0758 |
0 |
50500 |
6.58E-12 |
8 |
50 |
|
8 |
OPEN BB -F- |
1.00 mm female [OPEN] |
1.00 mm |
FEMALE |
28.4 |
543.356 |
-11.754 |
0.0793 |
0 |
999000 |
6.58E-12 |
8 |
50 |
|
2 |
OPEN LB -M- |
1.00 mm male [OPEN] |
1.00 mm |
MALE |
31.579 |
162.211 |
-4.0954 |
0.037 |
0 |
50500 |
6.58E-12 |
7.8 |
50 |
|
6 |
OPEN BB -M- |
1.00 mm male [OPEN] |
1.00 mm |
MALE |
31.043 |
274.897 |
-6.625 |
0.0539 |
0 |
999000 |
6.58E-12 |
8 |
50 |
|
|
|||||||||||||
|
Std. No. |
Label |
Description |
Connector |
Sex |
L0 H(e-12) |
L1 H(e-24)/Hz |
L2 H(e-33)/Hz^2 |
L3 H(e-42)/Hz^3 |
Fmin (MHz) |
Fmax (MHz) |
Delay (Sec) |
Loss (Gohm/Sec) |
Z0 (Ohm) |
|
3 |
SHORT 3 LB -F- |
1.00 mm female [SHORT 3] |
1.00 mm |
FEMALE |
2.419 |
-21.1901 |
-0.8034 |
0.0095 |
0 |
50500 |
8.15E-12 |
7.7 |
50 |
|
16 |
SHORT 1 HB -F- |
1.00 mm female [SHORT 1] |
1.00 mm |
FEMALE |
-0.9209 |
107.672 |
-1.553 |
0.0057 |
49900 |
999000 |
4.31E-12 |
8 |
50 |
|
17 |
SHORT 2 -F- |
1.00 mm female [SHORT 2] |
1.00 mm |
FEMALE |
11.2987 |
-384.343 |
3.251 |
-0.009 |
65000 |
999000 |
6.06E-12 |
8.55 |
50 |
|
18 |
SHORT 3 -F- |
1.00 mm female [SHORT 3] |
1.00 mm |
FEMALE |
8.2341 |
-305.298 |
3.7762 |
-0.015 |
49900 |
999000 |
8.15E-12 |
8 |
50 |
|
19 |
SHORT 4 -F- |
1.00 mm female [SHORT 4] |
1.00 mm |
FEMALE |
45.099 |
-1988.66 |
27.99 |
-0.1258 |
49900 |
75100 |
9.98E-12 |
8.23 |
50 |
|
7 |
SHORT 3 BB -F- |
1.00 mm female [SHORT 3] |
1.00 mm |
FEMALE |
4.3065 |
-156.379 |
1.9852 |
-0.0081 |
0 |
999000 |
8.15E-12 |
7.9 |
50 |
|
1 |
SHORT 3 LB -M- |
1.00 mm male [SHORT 3] |
1.00 mm |
MALE |
3.2053 |
-171.65 |
3.3888 |
-0.0208 |
0 |
50500 |
8.15E-12 |
7.74 |
50 |
|
12 |
SHORT 1 HB -M- |
1.00 mm male [SHORT 1] |
1.00 mm |
MALE |
4.4217 |
-174.59 |
2.2083 |
-0.0084 |
49900 |
999000 |
4.31E-12 |
8 |
50 |
|
13 |
SHORT 2 -M- |
1.00 mm male [SHORT 2] |
1.00 mm |
MALE |
-14.4155 |
484.395 |
-5.0055 |
0.0164 |
65000 |
999000 |
6.06E-12 |
8.51 |
50 |
|
14 |
SHORT 3 -M- |
1.00 mm male [SHORT 3] |
1.00 mm |
MALE |
1.14 |
24.8423 |
-0.9462 |
0.006 |
49900 |
999000 |
8.15E-12 |
8 |
50 |
|
15 |
SHORT 4 -M- |
1.00 mm male [SHORT 4] |
1.00 mm |
MALE |
3.6474 |
-113.206 |
1.1075 |
-0.0027 |
49900 |
75100 |
9.98E-12 |
8.2 |
50 |
|
5 |
SHORT 3 BB -M- |
1.00 mm male [SHORT 3] |
1.00 mm |
MALE |
0.2885 |
40.2472 |
-0.9816 |
0.0057 |
0 |
999000 |
8.15E-12 |
7.93 |
50 |
|
|
|||||||||||||
|
Std. No. |
Label |
Description |
Connector |
Sex |
Fixed/Sliding |
Arbitary Imp |
Offset Load |
Fmin (MHz) |
Fmax (MHz) |
Delay (Sec) |
Loss (Gohm/Sec) |
Z0 (Ohm) |
|
|
9 |
50 GHz LOAD -F- |
1.00 mm female 50 GHz LOAD |
1.00 mm |
FEMALE |
FIXED |
OFF |
OFF |
0 |
50000 |
0.00E+00 |
0 |
50 |
|
|
10 |
BROADBAND -F- |
1.00 mm female broadband LOAD |
1.00 mm |
FEMALE |
FIXED |
OFF |
OFF |
0 |
999000 |
0.00E+00 |
0 |
50 |
|
|
23 |
50 GHz MATCH -F- |
1.00 mm female 50 GHz LOAD |
1.00 mm |
FEMALE |
FIXED |
OFF |
OFF |
0 |
55500 |
1.00E+05 |
0 |
50 |
|
|
24 |
50 GHz LOAD -M- |
1.00 mm male 50 GHz LOAD |
1.00 mm |
MALE |
FIXED |
OFF |
OFF |
0 |
50500 |
0.00E+00 |
0 |
50 |
|
|
21 |
50 GHz MATCH -M- |
1.00 mm male 50 GHz LOAD |
1.00 mm |
MALE |
FIXED |
OFF |
OFF |
0 |
55500 |
1.00E+05 |
0 |
50 |
|
|
22 |
BROADBAND -M- |
1.00 mm male broadband LOAD |
1.00 mm |
MALE |
FIXED |
OFF |
OFF |
0 |
999000 |
0.00E+00 |
0 |
50 |
|
|
|
|||||||||||||
|
Std. No. |
Label |
Description |
Connector Port1 |
Sex Port1 |
Connector Port2 |
Sex Port2 |
Fmin (MHz) |
Fmax (MHz) |
Delay (Sec) |
Loss (Gohm/Sec) |
Z0 (Ohm) |
|
|
|
11 |
THRU |
Insertable thru standard |
1.00 mm |
MALE |
1.00 mm |
FEMALE |
0 |
999000 |
0.00E+00 |
0 |
50 |
|
|
|
|
|||||||||||||
|
|
|||||||||||||
|
Connector |
Description |
Sex |
Media |
Min Freq(MHz) |
Max Freq(MHz) |
Cutoff Freq(MHz) |
tà |
|
|||||
|
1.00 mm |
1.00 mm female |
FEMALE |
COAX |
0 |
999000 |
0 |
tà |
|
|||||
|
1.00 mm |
1.00 mm male |
MALE |
COAX |
0 |
999000 |
0 |
tà |
|
|||||
|
|
|||||||||||||
|
|
|||||||||||||
|
|
|||||||||||||
|
SOLT Class Assignments |
|
||||||||||||
|
|
|||||||||||||
|
Class Label |
A |
B |
C |
D |
E |
F |
G |
H |
I |
J |
K |
|
|
|
S11A |
4 |
18 |
2 |
14 |
|
||||||||
|
S11B |
3 |
16 |
1 |
12 |
|
||||||||
|
S11C |
9 |
17 |
19 |
24 |
13 |
15 |
|
||||||
|
S22A |
4 |
18 |
2 |
14 |
|
||||||||
|
S22B |
3 |
16 |
1 |
12 |
|
||||||||
|
S22C |
9 |
17 |
19 |
24 |
13 |
15 |
|
||||||
|
FWD MATCH |
11 |
|
|||||||||||
|
FWD TRAN |
11 |
|
|||||||||||
|
REV MATCH |
11 |
|
|||||||||||
|
REV TRAN |
11 |
|
|||||||||||
|
ISOLATION |
10 |
22 |
|
||||||||||
|
|
|||||||||||||
|
|
|||||||||||||
|
TRL Class Assignments |
|
||||||||||||
|
|
|||||||||||||
|
Class Label |
A |
B |
C |
D |
E |
F |
G |
|
|||||
|
TRL THRU |
11 |
|
|||||||||||
|
TRL REFLECT |
7 |
5 |
|
||||||||||
|
TRL LINE |
23 |
21 |
|
||||||||||
|
FWD MATCH |
11 |
|
|||||||||||
|
REV MATCH |
11 |
|
|||||||||||
|
ISOLATION |
10 |
22 |
|
||||||||||
|
|
|||||||||||||
|
Calibration Reference Z0 = |
|
||||||||||||
|
SYSTEM Z0 |
|
||||||||||||
|
|
|||||||||||||
|
Testport Reference Plane = |
|
||||||||||||
|
THRU STANDARD |
|
||||||||||||