Click the links below to view, then download, the Cal Kit Standard Definitions.
Learn how to install the files on your Network Analyzer.
|
RF |
||||||||
|
Model |
Description |
PNA * |
ENA |
ENA-L |
8510 |
8753D |
8753E/ES/ET 872xES/ET |
872xD |
|
85031B |
7 mm Calibration Kit |
In F/W |
X* |
Not Supported |
In F/W |
In F/W |
In F/W | |
| 85032B/E | 50 Ohm Type-N Calibration Kit |
In F/W ** |
In F/W ** |
Not Supported |
In F/W |
In F/W |
In F/W | |
| 85032F | 50 Ohm Type-N Calibration Kit |
In F/W ** |
In F/W ** |
Not Supported |
In F/W |
Not Supported | ||
| 85033D | 3.5 mm Calibration Kit |
In F/W |
In F/W |
Not Supported |
In F/W |
In F/W |
In F/W | |
| 85033E | 3.5 mm Calibration Kit |
In F/W |
In F/W |
Not Supported |
In F/W |
Not Supported | ||
|
85036B/E |
75 Ohm Type-N Calibration Kit |
In F/W ** |
In F/W ** |
Not Supported |
In F/W |
In F/W |
In F/W | |
| 85038A | 7-16 Calibration Kit |
In F/W |
In F/W |
Not Supported |
||||
|
85039B |
75 Ohm Type F Calibration Kit |
In F/W |
In F/W |
Not Supported |
Not Supported | |||
|
Microwave |
||||||
|
Model |
Description |
PNA |
ENA |
ENA-L |
8510 |
872xD/ES/ET |
|
85050B |
7 mm Calibration Kit |
X* |
X* |
In F/W | ||
| 85050C | 7 mm Precision Calibration Kit |
In F/W |
X* |
In F/W | ||
|
85050D |
7 mm Economy Calibration Kit |
In F/W |
X* |
In F/W | ||
| 85052B | 3.5 mm Calibration Kit |
X* |
X* |
In F/W | ||
| 85052C | 3.5 mm Precision TRL Cal Kit |
In F/W |
N/A |
In F/W | ||
| 85052D | 3.5 mm Economy Calibration Kit |
In F/W |
In F/W |
In F/W | ||
|
85054B |
50 Ohm Type-N Calibration Kit |
X* |
X* |
In F/W | ||
| 85054D | 50 Ohm Type-N Economy Cal Kit |
In F/W** |
X* |
In F/W | ||
| 85056A | 2.4 mm Calibration Kit |
X* |
X* |
In F/W | ||
| 85056D | 2.4 mm Economy Calibration Kit |
In F/W |
X* |
In F/W | ||
|
85056K |
2.4mm and 2.92 mm Calibration Kit. |
In F/W |
X* |
In F/W | ||
|
85058B |
1.85 mm Calibration Kit |
N/A |
N/A |
N/A |
Not Supported | |
|
85058B |
1.85 mm Calibration Kit (Data Based) |
N/A |
N/A |
N/A |
Not Supported | |
|
85058BP |
1.85 mm Calibration Kit (Polynomial) |
X* |
X* |
N/A |
Not Supported | |
|
85058D |
1.85 mm Calibration Kit |
N/A |
N/A |
N/A |
Not Supported | |
|
85058E |
1.85 mm Economy Calibration Kit |
N/A |
N/A |
N/A |
Not Supported | |
|
85058E |
1.85 mm Economy Calibration Kit (Data Based) |
N/A |
N/A |
N/A |
Not Supported | |
|
85058EP |
1.85 mm Economy Calibration Kit (Polynomial) |
X* |
X* |
N/A |
Not Supported | |
|
85059A |
1.0 mm Multi-short banded Calibration Kit |
N/A |
N/A |
N/A |
Not Supported | |
|
85059A |
1.0 mm Open-Short-Load Broadband Calibration Kit |
N/A |
N/A |
N/A |
Not Supported | |
|
85059A |
1.0 mm Calibration/Verification Kit (Data Based) |
N/A |
N/A |
N/A |
Not Supported | |
|
85059AP |
1.0 mm Calibration/Verification Kit (Polynomial) |
X* |
X* |
N/A |
Not Supported | |
|
Waveguide |
||||||
|
Model |
Description |
PNA |
ENA |
ENA-L |
8510 |
8720D |
|
X11644A |
X Band 90 Calibration Kit |
In F/W |
N/A |
|||
| P11644A | P Band WG 62 Calibration Kit |
In F/W |
N/A |
|||
| K11644A | K Band WG 42 Calibration Kit |
In F/W |
N/A |
|||
| R11644A | R Band WR 28 Calibration Kit |
X* |
N/A |
|||
| Q11644A | Q Band WR 22 Calibration Kit |
X* |
N/A |
Not Supported | ||
| U11644A | U Band WR 19 Calibration Kit |
X* |
N/A |
Not Supported | ||
| V11644A | V Band WR 15 Calibration Kit |
X* |
N/A |
Not Supported | ||
|
W11644A |
W Band WR 10 Calibration Kit |
X* |
N/A |
Not Supported | ||
* Cal Kit definitions must be manually typed into the ENA.
** The Cal standard sex, used in the pre-defined calibration standard label of the ENA / ENA-l firmware, indicates the connector sex of the test port end. It is the opposite sex from the connector sex of the cal standard or DUT end.
Last modified:
|
August 6, 2010 |
Separated PNA/ENA Updated the D53N5F download per PY |
|
October 5, 2007 |
Added 'Not supported' and 'In FW' entries |