Keysight Calibration Kit Definitions

 

Click the links below to view, then download, the Cal Kit Standard Definitions.

Learn how to install the files on your Network Analyzer.

Model Description PNA ENA ENA-L 8510 8753D 872xD 8753E/ES/ET 872xES/ET
85031B 7 mm Calibration Kit
(DC -- 6 GHz)
X In F/W X Not Supported In F/W In F/W In F/W In F/W
85032B/E 50 Ohm Type-N Calibration Kit
(DC -- 6 GHz)
X In F/W ** In F/W ** Not Supported In F/W In F/W In F/W In F/W
85032F 50 Ohm Type-N Calibration Kit
(DC -- 9 GHz)
X In F/W ** In F/W ** Not Supported D53N5F Not Supported In F/W In F/W
85033D 3.5 mm Calibration Kit
(DC -- 6 GHz)
X In F/W In F/W Not Supported In F/W In F/W In F/W In F/W
85033E 3.5 mm Calibration Kit
(DC -- 9 GHz)
X In F/W In F/W Not Supported D5335E Not Supported In F/W In F/W
85036B/E 75 Ohm Type-N Calibration Kit X In F/W ** In F/W ** Not Supported In F/W In F/W In F/W In F/W
85038A 7-16 Calibration Kit X In F/W In F/W CK_716A Not Supported D2X38A E5338A E5338A
85039B 75 Ohm Type F Calibration Kit X In F/W In F/W Not Supported D5339B Not Supported E5339B E5339B
85050B 7 mm Calibration Kit X* X* X* CK_7MMB2 Not Supported In F/W Not Supported In F/W
85050C 7 mm Precision Calibration Kit X In F/W X* CK_7MMC2 Not Supported In F/W Not Supported In F/W
85050D 7 mm Economy Calibration Kit X In F/W X* CK_7MMD Not Supported In F/W Not Supported In F/W
85052B 3.5 mm Calibration Kit X X* X* CK_35MMB Not Supported In F/W Not Supported In F/W
85052C 3.5 mm Precision Calibration Kit X In F/W N/A CK_35MMC Not Supported In F/W Not Supported In F/W
85052D 3.5 mm Economy Calibration Kit X In F/W In F/W CK_35MMD Not Supported In F/W Not Supported In F/W
85054B 50 Ohm Type-N Calibration Kit X X* X* CK_NTYPB2 Not Supported In F/W Not Supported In F/W
85054D 50 Ohm Type-N Economy Calibration Kit X In F/W ** X* CK_NTYPD2 Not Supported In F/W Not Supported In F/W
85056A 2.4 mm Calibration Kit X X* X* CK_24MMA Not Supported In F/W Not Supported In F/W
85056D 2.4 mm Economy Calibration Kit X In F/W X* CK_24MMD Not Supported In F/W Not Supported In F/W
85056K 2.4 mm and 2.92 mm Calibration Kit X In F/W X* CK_292MM Not Supported In F/W Not Supported In F/W
85058B 1.85 mm Calibration Kit N/A N/A N/A CK_185MMBA2 Not Supported Not Supported Not Supported Not Supported
85058B 1.85 mm Calibration Kit (Data Based) X N/A N/A N/A Not Supported Not Supported Not Supported Not Supported
85058BP 1.85 mm Calibration Kit (Polynomial) X X* X* N/A Not Supported Not Supported Not Supported Not Supported
85058D 1.85 mm Calibration Kit N/A N/A N/A CK_185MMD Not Supported Not Supported Not Supported Not Supported
85058E 1.85 mm Economy Calibration Kit N/A N/A N/A CK_185MMEA2 Not Supported Not Supported Not Supported Not Supported
85058E 1.85 mm Economy Calibration Kit (Data Based) X N/A N/A N/A Not Supported Not Supported Not Supported Not Supported
85058EP 1.85 mm Economy Calibration Kit (Polynomial) X X* X* N/A Not Supported Not Supported Not Supported Not Supported
85059A 1.0 mm Multi-short banded Calibration Kit N/A N/A N/A CK_1MMA Not Supported Not Supported Not Supported Not Supported
85059A 1.0 mm Open-Short-Load Broadband Calibration Kit N/A N/A N/A CK_1MMB Not Supported Not Supported Not Supported Not Supported
85059A 1.0 mm Calibration/Verification Kit (Data Based) X N/A N/A N/A Not Supported Not Supported Not Supported Not Supported
85059AP 1.0 mm Calibration/Verification Kit (Polynomial) X X* X* N/A Not Supported Not Supported Not Supported Not Supported
Waveguide
Model Description PNA ENA ENA-L 8510 872xD/ES/ET
X11644A X-Band WR 90 Calibration Kit X In F/W N/A CK_WR90A WR90A1
P11644A P-Band WR 62 Calibration Kit X In F/W N/A CK_WR62A WR62A1
K11644A K-Band WR 42 Calibration Kit X In F/W N/A CK_WR42A WR42A1
R11644A R-Band WR 28 Calibration Kit X X* N/A CK_WR28A WR28A3
Q11644A Q-Band WR 22 Calibration Kit X X* N/A CK_WR22A Not Supported
U11644A U-Band WR 19 Calibration Kit X X* N/A CK_WR19A Not Supported
V11644A V-Band WR 15 Calibration Kit X X* N/A CK_WR15A Not Supported
W11644A W-Band WR 10 Calibration Kit X X* N/A CK_WR10A Not Supported

* Cal Kit definitions must be manually typed into the ENA.

** The Cal standard sex, used in the pre-defined calibration standard label of the ENA / ENA-L firmware, indicates the connector sex of the test port end. It is the opposite sex from the connector sex of the cal standard or DUT end.

Last modified:

August 6, 2010 Separated PNA/ENA
Updated the D53N5F download per PY
October 5, 2007 Added 'Not supported' and 'In FW' entries