| Product Number | Description | Type | Upgrade Contents | Minimum Firmware | Minimum Hardware | Required Options Before Upgrade | Adjustments required after installation |
Installed by | Installation note |
|---|---|---|---|---|---|---|---|---|---|
| N5230AU-010 | Add Time Domain Operation | Software | License | None | None | None | None | Customer | |
| N5230AU-080 | Add Frequency Offset Mode | Software | License | None | None | None | None | Customer | |
| N5230AU-082 | Add Scalar Calibrated Converter Measurements | Software | License | None | None | 080 | None | Customer | |
| N5230AU-221 | Upgrade 2-Port N5230A to N5230C See Model Change Note See Detailed Model Upgrade Info. |
Hardware | Hardware Kit | A.08.04 | 1.1 GHz CPU | None | Source Adjust Receiver Adjust |
Agilent Service Center or Customer Who Can Run Performance Tests & Adjustments | |
| N5230AU-241 | Upgrade 4-Port N5230A to N5230C See Model Change Note See Detailed Model Upgrade Info. |
Hardware | Hardware Kit | A.08.04 | 1.1 GHz CPU | None | Source Adjust Receiver Adjust |
Agilent Service Center or Customer Who Can Run Performance Tests & Adjustments | |
| N5230AU-550 | Add Full 4 Port Capability | Software | License | None | None | None | None | Customer | |
| N5230AU-551 | Add Full N-Port Capability | Software | License | None | None | None | None | Customer | |
| N5230AU-901 | Active Measurement Configuration for 6 GHz or 13.5 GHz 2-port (Configuration 020 to 025 or 120 to 125) | Hardware | Hardware Kit | None | None | 020 or 120 | Source Adjust Receiver Adjust |
Agilent Service Center or Customer Who Can Run Performance Tests & Adjustments | |
| N5230AU-921 | Active Measurement Configuration for 20 GHz 2-port (Configuration 220 to 225) Serial Numbers MY4500xxxx and below |
Hardware | Hardware Kit | None | None | 220 | Source Adjust Receiver Adjust |
Agilent Service Center or Customer Who Can Run Performance Tests & Adjustments (2.5 hr install; 4.5 hr cal) |
|
| N5230AU-922 | Active Measurement Configuration for 20 GHz 2-port (Configuration 220 to 225) Serial Numbers MY4640xxxx and above |
Hardware | Hardware Kit | None | None | 220 | Source Adjust Receiver Adjust |
Agilent Service Center or Customer Who Can Run Performance Tests & Adjustments (2.5 hr install; 4.5 hr cal) |
|
| N5230AU-926 | Active Measurement Configuration for 20 GHz 4-port (Configuration 240 to 245) | Hardware | Hardware Kit | None | None | 240 | Source Adjust Receiver Adjust |
Agilent Service Center or Customer Who Can Run Performance Tests & Adjustments (2.5 hr install; 4.5 hr cal) |
|
| N5230AU-927 | Add Second Source for 20 GHz 4-port (Configuration 245 to 246) | Hardware | Hardware Kit | None | None | 245 | Source Adjust Receiver Adjust |
Agilent Service Center or Customer Who Can Run Performance Tests & Adjustments (2.5 hr install; 4.5 hr cal) |
|
| N5230AU-928 | Add Second Source for 13.5 GHz 4-port (Configuration 145 to 146) | Hardware | Hardware Kit | None | None | 145 | Source Adjust Receiver Adjust |
Agilent Service Center or Customer Who Can Run Performance Tests & Adjustments (2.5 hr install; 4.5 hr cal) |
|
| N5230AU-941 | Active Measurement Configuration for 40 GHz or 50 GHz 2-port (Configuration 420 to 425 or 520 to 525) | Hardware | Hardware Kit | None | None | 420 or 520 | Source Adjust Receiver Adjust |
Agilent Service Center or Customer Who Can Run Performance Tests & Adjustments (2.5 hr install; 4.5 hr cal) |
|
| N5230AU-960 | Upgrade 6 GHz Passive or Active Configuration to 13.5 GHz Operation | Software | License | None | None | 020 or 025 | Source Adjust Receiver Adjust |
Agilent Service Center or Customer Who Can Run Performance Tests & Adjustments (1.0 hr install; 4.5 hr cal) |
|
| N5230AU-966 | Upgrade 13.5 GHz 4-Pport Passive or Active Configuration to 20 GHz Operation | Software | License | None | None | 140 or 145 or 146 | Source Adjust Receiver Adjust |
Agilent Service Center or Customer Who Can Run Performance Tests & Adjustments (1.0 hr install; 4.5 hr cal) |
|
| N5230AU-971 | Upgrade 20 GHz Passive Configuration to 40 GHz Operation | Hardware | Hardware Kit and License | None | None | 220 or 420 | Source Adjust Receiver Adjust |
Agilent Service Center or Customer Who Can Run Performance Tests & Adjustments (2.5 hr install; 4.5 hr cal) |
|
| N5230AU-973 | Upgrade 20 GHz Active Configuration to 40 GHz Operation | Hardware | Hardware Kit and License | None | None | 225 or 425 | Source Adjust Receiver Adjust |
Agilent Service Center or Customer Who Can Run Performance Tests & Adjustments (2.5 hr install; 4.5 hr cal) |
|
| N5230AU-990 | Upgrade 40 GHz Passive or Active Configuration to 50 GHz Operation | Software | License | None | None | 420 or 425 | Source Adjust Receiver Adjust |
Agilent Service Center or Customer Who Can Run Performance Tests & Adjustments (1.0 hr install; 4.5 hr cal) |
Model Change Note:
Please note that existing software licenses are no longer valid when the model number is changed.
Please contact the Component Test Division to
have new software licenses issued.
Frequency Range Upgrade Note:
We offer frequency range upgrade kits to change a 2-port 6 GHz PNA-L to 13.5 GHz (option 960),
a 2-port 20 GHz PNA-L to 40 GHz (option 971/973), and a 2-port 40 GHz PNA-L to 50 GHz (option 990).
However, we do not offer a 2-port 13.5 GHz to 20 GHz upgrade kit. This is because the 6 and 13.5
GHz PNA-L was designed with a set of hardware which is very different than that in the 20 GHz
PNA-L. To change the frequency range would require replacing about $25,000 worth of hardware.
It is much more cost-effective to trade in your 13.5 GHz PNA-L toward the purchase of a new 20
GHz PNA-L. If you are still interested in pursuing this upgrade path, please contact the
Component Test Division.
For additional information, contact the support email node.