The minimum firmware version required for this product is A.07.20. Options which require a later version are listed with a different minimum firmware version.
| Product Number | Description | Type | Upgrade Contents | Minimum Firmware | Minimum Hardware | Required Options Before Upgrade | Adjustments required after installation |
Installed by | Installation note |
|---|---|---|---|---|---|---|---|---|---|
| N5242AU-008 | Add Pulsed RF Measurement Capability | Software | License | A.09.20.06 | None | 025 | None | Customer | |
| N5242AU-010 | Add Time Domain Operation | Software | License | None | None | None | None | Customer | |
| N5242AU-020 | Add IF Inputs for Antenna and mm-Wave | Software | License | None | None | None | None | Customer | |
| N5242AU-021 | Add Pulse Modulator to 1st Internal Source | Software | License | None | None | None | None | Customer | |
| N5242AU-022 | Add Pulse Modulator to 2nd Internal Source | Software | License | None | None | None | None | Customer | |
| N5242AU-025 | Add Four Internal Pulse Generators | Software | License | None | None | None | None | Customer | |
| N5242AU-028 | Add Basic Noise Figure Measurements | Software | License | A.09.20.06 | None | None | None | Customer | |
| N5242AU-080 | Add Frequency Offset Mode | Software | License | None | None | None | None | Customer | |
| N5242AU-082 | Add Scalar Calibrated Converter Measurements | Software | License | None | None | 080 | None | Customer | |
| N5242AU-083 | Add Vector and Scalar Calibrated Converter Measurements | Software | License | None | None | 080 | None | Customer | |
| N5242AU-084 | Add Embedded LO Measurements | Software | License | A.07.50 | None | at least one of: 028,029,H29,082,083,086,087 | None | Customer | |
| N5242AU-086 | Add Gain Compression Application | Software | License | A.08.00 | None | None | None | Customer | |
| N5242AU-087 | Add Intermodulation Distortion Measurements | Software | License and new Synthesizer boards | A.08.00 | None | 224 or 423,080 | None | Customer if newer instrument. Otherwise, Agilent Service Center or Customer Who Can Run Performance Tests & Adjustments | pdf note |
| N5242AU-088 | Add Source Phase Control | Software | License | None | None | None | None | Customer | |
| N5242AU-118 | Add Fast CW Mode | Software (some Hardware for older instruments) | License and new SPAM board | A.08.00 | None | None | None | Customer if newer instrument. Otherwise, Agilent Service Center or Customer Who Can Run Performance Tests & Adjustments | pdf note |
| N5242AU-460 | Add Integrated TMSA Application | Software | License | A.08.00 | None | None | None | Customer | |
| N5242AU-510 | Add Nonlinear Component Characterization | Software | License | A.08.00 | None | 400, 419 or H85, 080 | None | Customer | |
| N5242AU-514 | Add Nonlinear X-Parameters | Software | License | A.08.00 | None | 400, 419 or H85, 423, 080, 510 | None | Customer | |
| N5242AU-518 | Add Nonlinear Pulse Envelope Domain | Software | License | A.08.00 | None | 400, 419 or H85, 080, and 510 or 514 | None | Customer | |
| N5242AU-520 | Add Arbitrary Load Impedance for X-Parameters | Software | License | A.08.33 | None | 400, 419 or H85, 423, 080, 510, and 514 | None | Customer | |
| N5242AU-551 | Add N-Port Calibrated Measurements | Software | License | A.08.00 | None | None | None | Customer | |
| N5242AU-897 | Add Built-In Performance Test Software for Agilent Inclusive Calibration, Perpetual License | Software | License | None | None | None | None | Customer | |
| N5242AU-898 | Add Built-In Performance Test Software for Standards Compliant Calibration, Perpetual License | Software | License | None | None | None | None | Customer | |
| N5242AU-921 | Add Extended Power Range and Bias-Tees to 2-Port Analyzer (Option 219 Upgrade) | Hardware | Hardware and Installation Service | None | None | 200 | Source Adjust Receiver Adjust |
Agilent Service Center or Customer Who Can Run Performance Tests & Adjustments (3.5 hr install; 4.5 hr cal) |
|
| N5242AU-922 | Add Internal Second Source, Combiner and Mechanical Switches to 2-Port Analyzer (Option 224 Upgrade) | Hardware | Hardware and Installation Service | None | None | 200,219,080 | Source Adjust Receiver Adjust |
Agilent Service Center or Customer Who Can Run Performance Tests & Adjustments (5.5 hr install; 4.5 hr cal) |
|
| N5242AU-924 | Add Noise Figure Measurements to 2-Port Analyzer (Option 029 Upgrade) | Hardware | Hardware and Installation Service | A.08.04 | None | 200,219,080 | Source Adjust Receiver Adjust N.F. Adjust |
Agilent Service Center or Customer Who Can Run Performance Tests & Adjustments (5.5 hr install; 4.5 hr cal) |
|
| N5242AU-926 | Add Extended Power Range and Bias-Tees to 4-Port Analyzer (Option 419 Upgrade) | Hardware | Hardware and Installation Service | None | None | 400 | Source Adjust Receiver Adjust |
Agilent Service Center or Customer Who Can Run Performance Tests & Adjustments (3.5 hr install; 4.5 hr cal) |
|
| N5242AU-927 | Add Internal Combiner and Mechanical Switches to 4-port Analyzer (option 423 upgrade) | Hardware | Hardware and Installation Service | None | None | 400,419,080 | Source Adjust Receiver Adjust |
Agilent Service Center or Customer Who Can Run Performance Tests & Adjustments (5.5 hr install; 4.5 hr cal) |
|
| N5242AU-929 | Add Noise Figure Measurements to 4-Port Analyzer (Option 029 Upgrade) | Hardware | Hardware and Installation Service | A.08.04 | None | 400,419,080 | Source Adjust Receiver Adjust N.F. Adjust |
Agilent Service Center or Customer Who Can Run Performance Tests & Adjustments (5.5 hr install; 4.5 hr cal) |
|
| N5242AU-940 | Add 4-Port Operation to Base 2-Port Analyzer (Option 200 to 400 Upgrade) | Hardware | Hardware and Installation Service | None | None | 200 | Source Adjust Receiver Adjust |
Agilent Service Center or Customer Who Can Run Performance Tests & Adjustments (5.5 hr install; 4.5 hr cal) |
|
| N5242AU-942 | Add 4-Port Operation to 2-Port Analyzer with Option 219 (Option 200,219 to 400,419 Upgrade) | Hardware | Hardware and Installation Service | None | None | 200,219 | Source Adjust Receiver Adjust |
Agilent Service Center or Customer Who Can Run Performance Tests & Adjustments (5.5 hr install; 4.5 hr cal) |
|
| N5242AU-944 | Add 4-Port Operation to 2-Port Analyzer with Option 224 (Option 200,219,224 to 400,419,423 Upgrade) | Hardware | Hardware and Installation Service | None | None | 200,219,224 | Source Adjust Receiver Adjust |
Agilent Service Center or Customer Who Can Run Performance Tests & Adjustments (5.5 hr install; 4.5 hr cal) |
|
| N5242AU-H85 | Add High Power Configurable Capability (Option H85 Upgrade) | Hardware | Hardware and Installation Service | None | None | 200,219 or 400,419 | Source Adjust Receiver Adjust |
Agilent Service Center or Customer Who Can Run Performance Tests & Adjustments (1.0 hr install; 4.5 hr cal) |
Additional Options: Some options are listed in the About Network Analyzer dialog which are not shown above. Option 081, Reference Channel Transfer Switch, and 014, Configurable Test Set, come as standard equipment on all PNA-X analyzers. Option Pxx, Number of Test Ports, and Sxx, Number of Internal Sources, are determined by other hardware settings and are not user-settable. Options UNL and 016 are listed for cross-compatibility with other PNA option sets. These options are bundled together as option 219 or 419 on the PNA-X.
For additional information, contact the support email node.
Return to the PNA Family Service Homepage
Last Updated: 27 August 2010